{"product_id":"qj71gp21-sx-mitsubishi-cc-link-ie-controller-network-module","title":"QJ71GP21-SX | Mitsubishi CC-Link IE Controller Network Module","description":"\u003cp\u003eThe Mitsubishi QJ71GP21-SX, an integral component of the MELSEC-Q series, truly excels as a high-speed CC-Link IE Control Network module, purposefully designed to enhance distributed control in sophisticated industrial automation environments. This remarkable unit not only ensures robust, 1 Gbps data exchange across extensive optical fiber networks but also supports flexible configurations, ultimately boosting system reliability and overall performance for even the most demanding applications.\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse; margin-top: 20px;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color:#ADD8E6;\"\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eType of Unit\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eController Network Unit\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNetwork Interface\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCC-Link IE Control Network\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCommunication Speed\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 Gbps\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eConnection Cable\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOptical fiber cable (Multi-mode fiber)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eApplicable Connector\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDouble LC type connector\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMax. Number of Stations per Network\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e120 (1 control station + 119 normal stations)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOverall Cable Distance\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e66000 m (when 120 units are connected)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMaximum Inter-Station Distance\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e550 m\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNumber of Occupied I\/O Points\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e32 points\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDC 5V Internal Current Consumption\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.85 A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExternal Dimensions (H x W x D)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e98 mm x 27.4 mm x 90 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.18 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eConformance Standards\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCE, UL\/cUL, RoHS\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"itrustbot","offers":[{"title":"Default Title","offer_id":46575266988163,"sku":"QJ71GP21-SX","price":703.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/2599\/3603\/files\/60.png?v=1770648068","url":"https:\/\/itrustbot.com\/products\/qj71gp21-sx-mitsubishi-cc-link-ie-controller-network-module","provider":"itrustbot","version":"1.0","type":"link"}