{"product_id":"omron-k8ak-pa2-three-phase-phase-loss-relay","title":"Omron | K8AK-PA2 | Three-phase Phase-loss Relay","description":"\u003cp\u003eThe Omron K8AK-PA2 monitoring relay stands as a robust solution for ensuring the integrity of three-phase electrical systems. Engineered for precision, this 22.5mm wide device meticulously monitors for voltage asymmetry, phase loss, and incorrect phase sequence across both 3-wire and 4-wire configurations, thereby safeguarding industrial equipment and crucial automation processes. Its wide input voltage range, spanning from 220V to 480V AC, offers versatile applicability in diverse global installations, while its single SPDT relay output reliably signals detected faults. This unit is truly indispensable for maintaining operational continuity and preventing costly downtime in demanding B2B environments.\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color:#ADD8E6;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFunctions\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePhase Asymmetry, Phase Loss, Phase Sequence\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInstallation Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDIN Rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTerminal Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eScrew\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWidth\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e22.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eConnection Method\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3-wire, 4-wire\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRated Input Voltage (3-wire)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e380, 400, 415, 480 VAC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRated Input Voltage (4-wire)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e220, 230, 240, 277 VAC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOutput Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRelay\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eContact Description\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSPDT (Single-Pole Double-Throw)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOutput Relay Rating (Resistive Load)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5 A at 250 VAC, 5 A at 30 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAsymmetry Set Value\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2% to 22%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating Time (Asymmetry)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.1 to 30 s\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAmbient Operating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e-20 to 60¡ãC (no condensation or icing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIndicators\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower (Green), Relay Output (Yellow), Alarm Outputs (Red)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInput Load\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eApprox. 4.4 VA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":46751676661891,"sku":"K8AK-PA2","price":72.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/2599\/3603\/files\/k8ak-pa2.jpg?v=1772979535","url":"https:\/\/itrustbot.com\/products\/omron-k8ak-pa2-three-phase-phase-loss-relay","provider":"itrustbot","version":"1.0","type":"link"}