{"product_id":"omron-cs1w-pdc55-cs-series-process-analog-i-o-units","title":"Omron | CS1W-PDC55 | CS-series Process Analog I\/O Units","description":"\u003cp\u003eEngineered for exacting industrial environments, the Omron CS1W-PDC55 stands out as a high-performance, isolated DC input unit within the renowned SYSMAC CS-series. This sophisticated module, designed to enhance control system efficiency, expertly handles up to eight distinct analog inputs, converting diverse signal types like 0-10V, 4-20mA, or 1-5V into reliable digital data. Furthermore, its integrated functionalities, encompassing a square root function and comprehensive process value alarms, ensure not only superior data acquisition but also intelligent process monitoring, making it a critical component for optimizing automation workflows and maintaining system integrity.\u003c\/p\u003e\u003cbr\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color:#ADD8E6;\"\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUnit Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIsolated-type DC Input Unit\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Series\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSYSMAC CS-series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNumber of Inputs\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e8 (Analog)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInput Signal Types\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0 to 10 V, 0 to 5 V, 1 to 5 V, 4 to 20 mA (selectable per input)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMaximum Input Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e15 V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMaximum Input Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e30 mA\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eResolution\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1\/16,000 of full scale\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eConversion Period\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e250 ms\/8 inputs\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCurrent Consumption (5V DC)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.18 A (0.90 W)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCurrent Consumption (26V DC)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.06 A (1.56 W)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDimensions (W ¡Á H ¡Á D)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e35 ¡Á 130 ¡Á 126 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e450 g max \/ 0.45 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating Temperature\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0¡ãC to 55¡ãC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMounting Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBackplane\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eExternal Connection Terminals\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24-point removable terminal block (M3 screws)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIsolation\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBetween inputs and between inputs and PLC signals by transformer and photocoupler\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":46751673254019,"sku":"CS1W-PDC55","price":980.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/2599\/3603\/files\/CS1W-PDC55.jpg?v=1772979459","url":"https:\/\/itrustbot.com\/products\/omron-cs1w-pdc55-cs-series-process-analog-i-o-units","provider":"itrustbot","version":"1.0","type":"link"}