{"product_id":"fx5-4ad-pt-adp-mitsubishi-analog-input-module-for-temperature-sensors","title":"FX5-4AD-PT-ADP | Mitsubishi| Analog Input Module for Temperature Sensors","description":"\u003cp\u003eEngineered for exacting industrial automation tasks, the Mitsubishi FX5-4AD-PT-ADP serves as a crucial expansion adapter, expertly handling temperature measurements from resistance temperature detectors. This module reliably converts 4 channels of Pt100 or Ni100 sensor inputs into precise digital values, making it an indispensable component for accurate process control and monitoring within MELSEC iQ-F systems.\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color:#ADD8E6;\"\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNumber of Analog Input Points\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4 points (4 channels)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUsable RTD Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePt100 (JIS C 1604-1997, JIS C 1604-2013), Ni100 (DIN 43760 1987) - 3-wire type only\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDigital Output Value\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e16-bit signed binary\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTemperature Measuring Range (Pt100)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e-200 to +850¡æ (-328 to +1562¡ãF)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTemperature Measuring Range (Ni100)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e-60 to +250¡æ (-76 to +482¡ãF)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAccuracy (Pt100, at 25¡À5¡æ)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e¡À0.8¡æ\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAccuracy (Ni100, at 25¡À5¡æ)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e¡À0.4¡æ\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eResolution\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.1¡æ \/ 0.1 to 0.2¡ãF\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eConversion Speed\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eApprox. 85 ms\/channel\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIsolation Method\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBetween input terminal and CPU module: Photocoupler; Between input channels: Non-isolation\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInternal Power Supply (A\/D Conversion)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e24 V DC 20 mA (from CPU module)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInternal Power Supply (Interface)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5 V DC 10 mA (from CPU module)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMass (Weight)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eApprox. 0.1 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDimensions (W x H x D)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e17.6 mm x 106 mm x 89.1 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"itrustbot","offers":[{"title":"Default Title","offer_id":46575335932035,"sku":"FX5-4AD-PT-ADP","price":306.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/2599\/3603\/files\/fx5-4ad-pt-adp.jpg?v=1770649701","url":"https:\/\/itrustbot.com\/products\/fx5-4ad-pt-adp-mitsubishi-analog-input-module-for-temperature-sensors","provider":"itrustbot","version":"1.0","type":"link"}