{"product_id":"fx1n-1da-bd-mitsubishi-analog-output-board","title":"FX1N-1DA-BD | Mitsubishi| Analog output board","description":"\u003cp\u003eBoost your Mitsubishi FX1S or FX1N PLC's analog output with the FX1N-1DA-BD expansion board. This versatile module provides a single 12-bit analog output, configurable for both 0-10V and 4-20mA signals, ensuring precise control for varied industrial applications.\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color:#ADD8E6;\"\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFX1N-1DA-BD\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eManufacturer\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMitsubishi Electric\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModule Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAnalog Output Expansion Board\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCompatible PLCs\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMELSEC FX1S (V2.0+), FX1N (V2.0+) Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNumber of Analog Outputs\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1 Channel\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eVoltage Output Range\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDC 0 V to 10 V (External load resistance 2 k¦¸ to 1 M¦¸)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCurrent Output Range\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDC 4 mA to 20 mA (External load resistance 500 ¦¸ or less)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eVoltage Output Resolution\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e12-bit binary (2.5 mV)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCurrent Output Resolution\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e11-bit binary (8 ¦ÌA)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOverall Accuracy (Voltage)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e¡À1% (¡À0.1 V) of full scale 10V\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOverall Accuracy (Current)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e¡À1% (¡À0.16 mA) of full scale 16 mA\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eD\/A Conversion Time\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eApprox. 10 ms\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInternal (from base unit\/sequencer)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOccupied I\/O Points\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0 points\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOperating Ambient Temperature\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0 to 55 ¡ãC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0.02 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDimensions (W x H)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e43 x 38.5 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"itrustbot","offers":[{"title":"Default Title","offer_id":46575279472771,"sku":"FX1N-1DA-BD","price":51.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/2599\/3603\/files\/32.png?v=1770648274","url":"https:\/\/itrustbot.com\/products\/fx1n-1da-bd-mitsubishi-analog-output-board","provider":"itrustbot","version":"1.0","type":"link"}