{"product_id":"danfoss-fc111p75kt4-vlt-hvac-basic-drive","title":"Danfoss FC111P75KT4  Vlt HVAC Basic Drive","description":"\u003cp\u003e\n  The Danfoss FC111P75KT4 VLT? HVAC Basic Drive is an exceptionally efficient and robust solution for optimizing fan, pump, and compressor control in diverse HVAC systems. Seamlessly integrating advanced features like Automatic Energy Optimization and Fire Override Mode, this drive ensures significant energy savings while maintaining critical operational reliability.\n\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color:#ADD8E6;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eVLT? HVAC Basic Drive FC 111\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Rating\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e75 kW (100 HP)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSupply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3 x 380-480 VAC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOutput Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0-400 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEfficiency\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUp to 98% at full load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEnclosure Rating\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIP20 \/ Chassis Backplate\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAmbient Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUp to 50¡ãC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIntegrated EMC Filter\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBuilt-in (C1\/C2 according to EN 61800-3)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIntegrated DC Coils\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eYes, complies with EN 61000-3-12\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAnalog Inputs\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 (Voltage or Current)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eAnalog Outputs\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 (0\/4-20 mA)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRelay Outputs\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 Programmable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eStandard Communication Protocols\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBACnet, Modbus RTU, N2 Metasys, FLN Apogee, FC Protocol (via RS485)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color:#ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOverload Capacity\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e110% for 1 minute (every 10 minutes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":68365354631299,"sku":"FC111P75KT4","price":3471.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/2599\/3603\/files\/FC111-removebg-preview_ee6d165e-570b-4437-9794-40e8ebb96942.png?v=1794651820","url":"https:\/\/itrustbot.com\/products\/danfoss-fc111p75kt4-vlt-hvac-basic-drive","provider":"itrustbot","version":"1.0","type":"link"}