{"product_id":"danfoss-fc111p4k0t4-vlt-hvac-basic-drive","title":"Danfoss FC111P4K0T4  Vlt HVAC Basic Drive","description":"\u003cp\u003eEngineered for modern HVAC systems, the Danfoss FC111P4K0T4 VLT HVAC Basic Drive delivers exceptional energy efficiency and precise control for essential fan and pump applications. Its integrated communication capabilities, furthermore, ensure seamless integration into existing building management systems. This drive is particularly suited for straightforward tasks, prioritizing reliability and robust operation without compromising on efficiency.\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color: lightblue;\"\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr style=\"background-color: lightgray;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Series\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eVLT? HVAC Basic Drive FC 101\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: white;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFC111P4K0T4\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: lightgray;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRated Power\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4.0 kW\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: white;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSupply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3 x 380-480 V AC, ¡À10%\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: lightgray;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOutput Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0 - 100% of supply voltage\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: white;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOutput Frequency\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0 - 400 Hz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: lightgray;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProtection Class\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIP20\/Chassis (IP21\/Type 1 optional kit), IP54 options\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: white;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMax. Ambient Temperature\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e50¡ãC\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: lightgray;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRelative Humidity\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5-95% (non-condensing)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: white;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProgrammable Relay Outputs\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: lightgray;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIntegrated Fieldbuses\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBACnet, Modbus RTU, N2 Metasys, FLN Apogee, FC Protocol\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: white;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eEfficiency\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eUp to 98% or more at full load\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: lightgray;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIntegrated Features\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDC Coils, EMC Filters\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: white;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eMotor Protection\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eElectronic thermal overload, heatsink monitoring, short-circuit, earth fault, mains phase loss\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":68365362856067,"sku":"FC111P4K0T4","price":549.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/2599\/3603\/files\/FC111-removebg-preview_2bf54c89-7f51-40a5-870e-804de66e2516.png?v=1794651837","url":"https:\/\/itrustbot.com\/products\/danfoss-fc111p4k0t4-vlt-hvac-basic-drive","provider":"itrustbot","version":"1.0","type":"link"}