{"product_id":"danfoss-131b0149-fc-302p3k0t5e20h2xgc-frequency-inverters","title":"Danfoss 131B0149  FC-302P3K0T5E20H2XGC Frequency Inverters","description":"\u003cp\u003eEngineered for sophisticated industrial automation tasks, the Danfoss 131B0149 VLT? AutomationDrive FC 302 stands out as a robust and highly versatile 3.0 kW frequency inverter. This unit excels in managing a wide array of motor technologies, including both asynchronous and permanent magnet motors, moreover, its integrated motion control capabilities ensure exceptional precision for positioning and synchronization without requiring additional modules. Control engineers and purchasing managers alike will appreciate its flexible fieldbus integration, comprehensive safety features, and the inherent reliability built into every Danfoss VLT drive, making it an indispensable component for optimizing diverse machine operations, from conveyors and hoists to complex winding and packaging lines.\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse: collapse;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color:#ADD8E6;\"\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n            \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e131B0149\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eType Code\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFC-302P3K0T5E20H2XGCXXXSXXXXAXBXCXXXXDX\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProduct Series\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eVLT? AutomationDrive FC 302\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Rating\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3.0 kW (4 HP)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInput Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3 x 380-500 VAC (¡À10%)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInput Frequency\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e50\/60 Hz (¡À5%)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOutput Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0-100% of supply voltage\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOutput Frequency\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0-590 Hz (VxF), 0-300 Hz (Sensorless Flux), 0-1000 Hz (FC 302)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eContinuous Output Current (380-440V)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e7.2 A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOverload Capability\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e160% of rated output current for 60 seconds\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eProtection Class\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eIP20 \/ Chassis\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFrame Size\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eA2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eRFI Filter\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eH2 (EMC Class A2 \/ Category C3)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrake Chopper\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNot included (External solution required for brake duty)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eControl Panel\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eGraphical Local Control Panel (LCP 102)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePCB Coating\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCoated PCB\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#f2f2f2;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e268 x 90 x 205 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color:#ffffff;\"\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eNet Weight\u003c\/td\u003e\n            \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e4.04 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":68365475348611,"sku":"131B0149","price":1031.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0703\/2599\/3603\/files\/FC-302_ac7e06e7-9d38-40fa-970c-f06eef630426.jpg?v=1794652043","url":"https:\/\/itrustbot.com\/products\/danfoss-131b0149-fc-302p3k0t5e20h2xgc-frequency-inverters","provider":"itrustbot","version":"1.0","type":"link"}